連云區(qū)倍福伺服驅(qū)動(dòng)器維修熱線:F78C, Feedback "general": Initialization failed反饋“一般”:初始化失敗。The initialization of the feedback parameter channel has failed (EnDat).反饋參數(shù)通道的初始化失。EnDat)。
倍福交流伺服電機(jī)驅(qū)動(dòng)器維修:
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
診斷代碼(十六進(jìn)制)診斷代碼(Dez)
F78C 63372
Class Type類(lèi)別類(lèi)型
Error Runtime error
運(yùn)行時(shí)錯(cuò)誤
Standard Reaction Reset
標(biāo)準(zhǔn)反應(yīng)復(fù)位
The power stage is already switched off Execute Reset-Command (S-0-0099).
電源級(jí)已關(guān)閉執(zhí)行復(fù)位命令(S-0-0099)。
Possible Causes Solutions
可能的原因解決方案
The feedback line is defective. Check the line.
反饋線路有故障。檢查線路。
Wrong feedback system. Enter the correct feedback system.
錯(cuò)誤的反饋系統(tǒng)。輸入正確的反饋系統(tǒng)。
The feedback system is defective. Check the feedback system.
反饋系統(tǒng)有缺陷。檢查反饋系統(tǒng)。
An unknown hard- or software error has occurred.
出現(xiàn)未知的硬件或軟件錯(cuò)誤。
Disconnect the servo drive from the mains (including the 24 V power supply) and start a new attempt. 斷開(kāi)伺服驅(qū)動(dòng)器與電源(包括24 V電源)的連接,然后開(kāi)始新的嘗試。
If this error occurs repeatedly, please contact the Shanghai Yangon Electronic Customer Service Department。如果此錯(cuò)誤重復(fù)發(fā)生,請(qǐng)聯(lián)系上海仰光電子客戶(hù)服務(wù)部門(mén)。
轉(zhuǎn)載請(qǐng)注明出處:上海仰光電子科技專(zhuān)業(yè)伺服驅(qū)動(dòng)器維修,伺服電機(jī)維修